Biblio Discovery — Demo Discovery Service

35 hasil untuk "Aaron Yu"

Menampilkan 1–20 · 0,71 detik · RSS

  1. Artikel Jurnal

    Electronic Warfare Cyberattacks, Countermeasures, and Modern Defensive Strategies of UAV Avionics: A Survey

    Aaron Yu; Iuliia Kolotylo; Hashim A. Hashim dkk.

    IEEE Access, Vol. 13 · 2025 · Inggris · DOAJ Scopus

    Unmanned Aerial Vehicles (UAVs) play a pivotal role in modern autonomous air mobility, and the reliability of UAV avionics systems is critical to ensuring mission success, sustainability practices, and public safety. The success of UAV missions depends on effectively mitigating various aspects of…

  2. Artikel Jurnal Teks lengkap

    Biomechanical Effects of Diameters of Implant Body and Implant Platform in Bone Strain around an Immediately Loaded Dental Implant with Platform Switching Concept

    Hsuan Lung; Jui-Ting Hsu; Aaron Yu-Jen Wu dkk.

    Applied Sciences, Vol. 9 No. 10 · 2019 · Inggris · DOAJ Scopus

    Dental implants designed with platform switching have been used clinically to reduce crestal bone resorption. The aim of this study was to determine the biomechanical effects of loading types, diameter of platform, and implant diameter in bone strain around immediately loaded implants with platform…

  3. Artikel Jurnal Teks lengkap

    Effects of Positions and Angulations of Titanium Dental Implants in Biomechanical Performances in the All-on-Four Treatment: 3D Numerical and Strain Gauge Methods

    Aaron Yu-Jen Wu; Jui-Ting Hsu; Lih-Jyh Fuh dkk.

    Metals, Vol. 10 No. 2 · 2020 · Inggris · DOAJ Scopus

    In finite element (FE) simulations, the peak bone stresses were higher when loading with a cantilever extension (CE) than when loading without a CE by 33−49% in the cortical bone. In the in vitro experiments, the highest values of principal strain were all within the range of the minimum principal…

  4. Artikel Jurnal Teks lengkap

    Effects of implant length and 3D bone-to-implant contact on initial stabilities of dental implant: a microcomputed tomography study

    Jui-Ting Hsu; Aaron Yu-Jen Wu; Lih-Jyh Fuh dkk.

    BMC Oral Health, Vol. 17 No. 1 · 2017 · Inggris · DOAJ Scopus

    Abstract Background The influences of potential bone-to-implant contact (BIC) area (pBICA), BIC area (BICA), and three dimensional (3D) BIC percentage (3D BIC%; defined as BICA divided by pBICA) in relation to the implant length on initial implant stability were studied. Correlations between these…

    Juga tersedia di: PubMed Central

  5. Artikel Jurnal

    Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro test and finite element analysis

    Aaron Yu-Jen Wu; Jui-Ting Hsu; Lih-Jyh Fuh dkk.

    Journal of the Formosan Medical Association, Vol. 119 No. 10 · 2020 · Inggris · DOAJ Scopus

    Background/Purpose: Impact of the implant shape on the biomechanical performance of all-on-four treatment of dental implant is still unclear. This study evaluated the all-on-four treatment with four osseointegrated implants in terms of the biomechanical effects of implant design and loading…

  6. Artikel Jurnal Teks lengkap

    Computed tomographic analysis of maxillary sinus anatomy relevant to sinus lift procedures in edentulous ridges in Taiwanese patients

    Yu, Shun-Jen; Lee, Yi-Hao; Lin, Ching-Ping dkk.

    J Periodontal Implant Sci · 2019 · Inggris · PubMed Central

    PURPOSE: To analyze the maxillary sinus anatomy over edentulous ridges in the bilateral posterior maxillary area in Taiwanese patients using cone-beam computed tomography (CBCT). METHODS: In total, 101 anatomical sites from 61 patients, including 32 premolar and 69 molar regions, were analyzed…

  7. Artikel Jurnal Teks lengkap

    Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study

    Yu-Hsuan Chen; Yu-Ling Wu; Hung-Shyong Chen dkk.

    Journal of Functional Biomaterials, Vol. 14 No. 3 · 2023 · Inggris · DOAJ Scopus

    This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts…

    Juga tersedia di: PubMed Central

  8. Artikel Jurnal Teks lengkap

    Effect of Marginal Bone Integrity and Aftermarket Abutment Screws on Dental Implant Systems—A Preliminary Study with Finite Element Method

    Wu, Yu-Ling; Tsai, Ming-Hsu; Chen, Hung-Shyong dkk.

    Materials (Basel) · 2022 · Inggris · PubMed Central

    Bone resorption around implants is quite common, and the maturity and popularization of computer-aided design and computer-aided manufacturing (CAD/CAM) technology have made the use of aftermarket abutment screws more widespread. This study aimed to explore the biomechanical influence of these two…

  9. Artikel Jurnal Teks lengkap

    Biomechanical Evaluation of Bone Atrophy and Implant Length in Four Implants Supporting Mandibular Full-Arch-Fixed Dentures

    Huang, Heng-Li; Tsai, Hui-Ling; Wu, Yu-Ling dkk.

    Materials (Basel) · 2022 · Inggris · PubMed Central

    Residual alveolar ridge resorption often occurs after tooth extraction, which causes issues requiring further prothesis rehabilitation. A treatment concept referred to as all-on-four, involving fixed dentures supported with four implants, was recently developed. The current study aimed to determine…

  10. Artikel Jurnal Teks lengkap

    The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study

    Chih-Jen Lin; Ming-Hsu Tsai; Yu-Ling Wu dkk.

    Journal of Functional Biomaterials, Vol. 13 No. 3 · 2022 · Inggris · DOAJ Scopus

    Although laser irradiation and implantoplasty (IP) are both treatment options for peri-implantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface…

    Juga tersedia di: PubMed Central

  11. Artikel Jurnal

    Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses

    Aaron Yu-Jen Wu; Jui-Ting Hsu; Winston Chee dkk.

    Journal of the Formosan Medical Association, Vol. 115 No. 9 · 2016 · Inggris · DOAJ Scopus

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece…

  12. Artikel Jurnal Teks lengkap

    Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant–Abutment Connections: A Three-Dimensional Finite Element Study

    Pei-Shuang Wang; Ming-Hsu Tsai; Yu-Ling Wu dkk.

    Journal of Functional Biomaterials, Vol. 14 No. 10 · 2023 · Inggris · DOAJ Scopus

    The type of implant-abutment connection is one of the factors influencing the distribution of occlusal forces. This study aims to investigate the biomechanical performance of the mandibular all-on-4 treatment with different implant–abutment connections. Two connection types with 30° abutments and…

    Juga tersedia di: PubMed Central

  13. Artikel Jurnal Teks lengkap

    Effects of Marginal Bone Loss Progression on Stress Distribution in Different Implant–Abutment Connections and Abutment Materials: A 3D Finite Element Analysis Study

    Lin, Ching-Ping; Shyu, Yi-Ting; Wu, Yu-Ling dkk.

    Materials (Basel) · 2022 · Inggris · PubMed Central

    Peri-implantitis is a common implant-supported prosthesis complication, and marginal bone loss affects the stress distribution in implant systems. This three-dimensional finite element analysis study investigated how bone loss affects the implant assembly; in particular, models including two…

  14. Artikel Jurnal Teks lengkap

    Biomechanical effects of original equipment manufacturer and aftermarket abutment screws in zirconia abutment on dental implant assembly

    Wu, Yu-Ling; Tsai, Ming-Hsu; Chen, Hung-Shyong dkk.

    Sci Rep · 2020 · Inggris · PubMed Central

    The use of aftermarket computer-aided design/computer-assisted manufacturing (CAD/CAM) prosthesis components in dental implants has become popular. This study aimed to (1) compare the accuracy of aftermarket CAD/CAM screws with that of original equipment manufacturer (OEM) abutment screws and (2)…

  15. Artikel Jurnal Teks lengkap

    Comparing the Fracture Resistance and Modes of Failure in Different Types of CAD/CAM Zirconia Abutments with Internal Hexagonal Implants: An In Vitro Study

    Chang, Yu-Tsen; Wu, Yu-Ling; Chen, Hung-Shyong dkk.

    Materials (Basel) · 2022 · Inggris · PubMed Central

    Three groups of zirconia abutments (n = 5) consisting of different connection designs or manufacturers were investigated (All-Zr, ASC-Zr, and AM-Zr groups). All-electric dynamic test instruments were used to place static loading on a specimen with a crosshead speed set at 1 mm/min. A Kruskal–Wallis…