Biblio Discovery — Demo Discovery Service

23 hasil untuk "Ian Halliday"

Menampilkan 1–20 · 0,14 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Continuum Scale Non Newtonian Particle Transport Model for Hæmorheology

    Torsten Schenkel; Ian Halliday

    Mathematics, Vol. 9 No. 17 · 2021 · Inggris · DOAJ Scopus

    We present a continuum scale particle transport model for red blood cells following collision arguments, in a diffusive flux formulation. The model is implemented in FOAM, in a framework suitable for haemodynamics simulations and adapted to multi-scaling. Specifically, the framework we present is…

  2. Artikel Jurnal Teks lengkap

    Convergence, sampling and total order estimator effects on parameter orthogonality in global sensitivity analysis.

    Harry Saxton; Xu Xu; Torsten Schenkel dkk.

    PLoS Computational Biology, Vol. 20 No. 7 · 2024 · Inggris · DOAJ Scopus

    Dynamical system models typically involve numerous input parameters whose "effects" and orthogonality need to be quantified through sensitivity analysis, to identify inputs contributing the greatest uncertainty. Whilst prior art has compared total-order estimators' role in recovering "true"…

    Juga tersedia di: PLOS

  3. Artikel Jurnal Teks lengkap

    Sensitivity analysis of closed-loop one-chamber and four-chamber models with baroreflex.

    Karolina Tlałka; Harry Saxton; Ian Halliday dkk.

    PLoS Computational Biology, Vol. 20 No. 12 · 2024 · Inggris · DOAJ Scopus

    The baroreflex is one of the most important control mechanisms in the human cardiovascular system. This work utilises a closed-loop in silico model of baroreflex regulation, coupled to pulsatile mechanical models with (i) one heart chamber and 36-parameters and (ii) four chambers and 51 parameters…

    Juga tersedia di: PLOS

  4. Artikel Jurnal Teks lengkap

    Analysis of Blood Stasis for Stent Thrombosis Using an Advection-Diffusion Lattice Boltzmann Scheme

    Ruben van der Waerden; James Spendlove; James Entwistle dkk.

    Mathematics, Vol. 13 No. 3 · 2025 · Inggris · DOAJ Scopus

    An advection-diffusion solver was applied to assess how stent strut shape and position impact the development of a pro-thrombotic region within the stented human artery. Presented here is a suitably parameterised advection-diffusion equation with a source term that is spatially uniform within a…

  5. Artikel Jurnal

    P83 A PILOT STUDY TO ASSESS PEAK SYSTOLIC VELOCITY AS A POSSIBLE MARKER OF ATHEROSCLEROTIC BURDEN USING ULTRASOUND

    Carola Koenig; Mark Atherton; Marco Cavazzuti dkk.

    Artery Research, Vol. 20 · 2017 · Inggris · DOAJ Scopus

    Introduction: Ischemic heart disease (IHD) has been associated with lower peak systolic velocity (PSV) on penile Doppler measurements [1]. This study establishes whether carotid ultrasound (US) PSV was associated with computational fluid dynamics (CFD) outputs, which in turn may contribute to IHD…

  6. Artikel Jurnal

    Rethinking the Bland-Altman plot when quantifying virtual coronary physiology

    Daniel J. Taylor; Harry Saxton; Ian Halliday dkk.

    Frontiers in Cardiovascular Medicine, Vol. 12 · 2025 · Inggris · DOAJ Scopus

    Angiography-derived, or “virtual” fractional flow reserve (vFFR) is beginning to replace invasive assessment in some catheterisation laboratories. Despite its incorporation into clinical guidelines, recent clinical outcomes data have cast doubt over its effectiveness relative to invasive…

  7. Artikel Jurnal Teks lengkap

    The Use of Digital Coronary Phantoms for the Validation of Arterial Geometry Reconstruction and Computation of Virtual FFR

    Giulia Pederzani; Krzysztof Czechowicz; Nada Ghorab dkk.

    Fluids, Vol. 7 No. 6 · 2022 · Inggris · DOAJ Scopus

    We present computational fluid dynamics (CFD) results of virtual fractional flow reserve (vFFR) calculations, performed on reconstructed arterial geometries derived from a digital phantom (DP). The latter provides a convenient and parsimonious description of the main vessels of the left and right…

  8. Artikel Jurnal Teks lengkap

    The impact of experimental designs & system sloppiness on the personalisation process: A cardiovascular perspective

    Harry Saxton; Daniel J. Taylor; Grace Faulkner dkk.

    PLOS One, Vol. 20 No. 6 · 2025 · Inggris · PLOS Scopus

    To employ a reduced-order cardiovascular model as a digital twin for personalised medicine, it is essential to understand how uncertainties in the model’s input parameters affect its outputs. The aim is to identify a set of input parameters that can serve as clinical biomarkers, providing insight…

    Juga tersedia di: DOAJ, DOAJ

  9. Artikel Jurnal

    Sex differences in coronary microvascular resistance measured by a computational fluid dynamics model

    Daniel J. Taylor; Louise Aubiniere-Robb; Rebecca Gosling dkk.

    Frontiers in Cardiovascular Medicine, Vol. 10 · 2023 · Inggris · DOAJ Scopus

    BackgroundIncreased coronary microvascular resistance (CMVR) is associated with coronary microvascular dysfunction (CMD). Although CMD is more common in women, sex-specific differences in CMVR have not been demonstrated previously.AimTo compare CMVR between men and women being investigated for…

  10. Artikel Jurnal

    Refining Our Understanding of the Flow Through Coronary Artery Branches; Revisiting Murray’s Law in Human Epicardial Coronary Arteries

    Daniel J. Taylor; Jeroen Feher; Ian Halliday dkk.

    Frontiers in Physiology, Vol. 13 · 2022 · Inggris · DOAJ Scopus

    Background: Quantification of coronary blood flow is used to evaluate coronary artery disease, but our understanding of flow through branched systems is poor. Murray’s law defines coronary morphometric scaling, the relationship between flow (Q) and vessel diameter (D) and is the basis for minimum…

  11. Artikel Jurnal Teks lengkap

    The Complementary Value of Absolute Coronary Flow in the Assessment of Patients with Ischaemic Heart Disease (the COMPAC-Flow Study)

    Aubiniere-Robb, Louise; Gosling, Rebecca; Taylor, Daniel J dkk.

    Nat Cardiovasc Res · 2022 · Inggris · PubMed Central

    Fractional flow reserve (FFR) is the current gold-standard invasive assessment of coronary artery disease (CAD). FFR reports coronary blood flow (CBF) as a fraction of a hypothetical and unknown normal value. Although used routinely to diagnose CAD and guide treatment, how accurately FFR predicts…

  12. Artikel Jurnal Teks lengkap

    Integrating particle tracking with computational fluid dynamics to assess haemodynamic perturbation by coronary artery stents

    Luke Boldock; Amanda Inzoli; Silvia Bonardelli dkk.

    PLOS ONE, Vol. 17 No. 7 · 2022 · Inggris · PLOS Scopus

    Aims: Coronary artery stents have profound effects on arterial function by altering fluid flow mass transport and wall shear stress. We developed a new integrated methodology to analyse the effects of stents on mass transport and shear stress to inform the design of haemodynamically-favourable…

    Juga tersedia di: DOAJ

  13. Artikel Jurnal Teks lengkap

    Correction: Integrating particle tracking with computational fluid dynamics to assess haemodynamic perturbation by coronary artery stents

    Luke Boldock; Amanda Inzoli; Silvia Bonardelli dkk.

    PLOS ONE, Vol. 19 No. 11 · 2024 · Inggris · PLOS Scopus

    [This corrects the article DOI: 10.1371/journal.pone.0271469.].

    Juga tersedia di: DOAJ

  14. Artikel Jurnal Teks lengkap

    A Digital Twin to Predict Patient Response to Valve Replacement Following Aortic Stenosis

    Krzysztof Czechowicz; Grace H. Faulkner; Marcus Kelm dkk.

    Fluids, Vol. 11 No. 9 · 2026 · Inggris · DOAJ Scopus

    Lack of available data, ease of clinical use and lack of evidence for prognostic benefit are arguably the key limitations to clinical uptake for any model. This paper reports the development of an image-based analysis protocol, coupling 0D left heart and systemic circulation components with a 3D…