Biblio Discovery — Demo Discovery Service

49 results for "Radhouene Neji"

Showing 1–20 · 0.67 seconds · RSS

  1. Journal Article

    Feasibility of cardiac MR thermometry at 0.55 T

    Ronald Mooiweer; Charlotte Rogers; Rohini Vidya Shankar et al.

    Frontiers in Cardiovascular Medicine, Vol. 10 · 2023 · English · DOAJ Scopus

    Radiofrequency catheter ablation is an established treatment strategy for ventricular tachycardia, but remains associated with a low success rate. MR guidance of ventricular tachycardia shows promises to improve the success rate of these procedures, especially due to its potential to provide…

  2. Journal Article

    Automatic image-based tracking of gadolinium-filled balloon wedge catheters for MRI-guided cardiac catheterization using deep learning

    Alexander Paul Neofytou; Grzegorz Tomasz Kowalik; Rohini Vidya Shankar et al.

    Frontiers in Cardiovascular Medicine, Vol. 10 · 2023 · English · DOAJ Scopus

    IntroductionMagnetic Resonance Imaging (MRI) is a promising alternative to standard x-ray fluoroscopy for the guidance of cardiac catheterization procedures as it enables soft tissue visualization, avoids ionizing radiation and provides improved hemodynamic data. MRI-guided cardiac catheterization…

  3. Journal Article

    Phase‐Change Alloys Enable Localized Reversible Stiffening and Actuation in Steerable Eversion Tip‐Growing Robots

    Shamsa Al Harthy; S.M.Hadi Sadati; Shannon C. Stockdale et al.

    Advanced Intelligent Systems, Vol. 8 No. 3 · 2026 · English · DOAJ Scopus

    Tip‐growing eversion robots navigate complex, constrained environments through pressure‐driven shear‐free material unfolding at the tip—a locomotion strategy ideal for intraluminal interventions. However, their flexibility limits their force exertion and payload delivery, makes them prone to…

  4. Journal Article

    3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography

    Giulia Ginami; Radhouene Neji; Imran Rashid et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 19 No. 1 · 2017 · English · DOAJ Scopus

    Abstract Background Phase sensitive inversion recovery (PSIR) applied to late gadolinium enhancement (LGE) imaging is widely used in clinical practice. However, conventional 2D PSIR LGE sequences provide sub-optimal contrast between scar tissue and blood pool, rendering the detection of…

  5. Journal Article

    Characterization of quantitative susceptibility mapping in the left ventricular myocardium

    Andrew Tyler; Li Huang; Karl Kunze et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 26 No. 1 · 2024 · English · DOAJ Scopus

    ABSTRACT: Background: Myocardial quantitative susceptibility mapping (QSM) may offer better specificity to iron than conventional T2* imaging in the assessment of cardiac diseases, including intra-myocardial hemorrhage. However, the precision and repeatability of cardiac QSM have not yet been…

  6. Journal Article

    Active Tracking-based cardiac triggering for MR-thermometry during radiofrequency ablation therapy in the left ventricle

    Ronald Mooiweer; Rainer Schneider; Axel Joachim Krafft et al.

    Frontiers in Cardiovascular Medicine, Vol. 9 · 2022 · English · DOAJ Scopus

    Cardiac MR thermometry shows promise for real-time guidance of radiofrequency ablation of cardiac arrhythmias. This technique uses ECG triggering, which can be unreliable in this situation. A prospective cardiac triggering method was developed for MR thermometry using the active tracking (AT)…

  7. Journal Article

    Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping

    Haikun Qi; Aurelien Bustin; Thomas Kuestner et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 22 No. 1 · 2020 · English · DOAJ Scopus

    Abstract Background Cardiovascular magnetic resonance (CMR) T1ρ mapping can be used to detect ischemic or non-ischemic cardiomyopathy without the need of exogenous contrast agents. Current 2D myocardial T1ρ mapping requires multiple breath-holds and provides limited coverage. Respiratory gating by…

  8. Journal Article

    Fast reconstruction of SMS bSSFP myocardial perfusion images using noise map estimation network (NoiseMapNet): a head-to-head comparison with parallel imaging and iterative reconstruction

    Naledi Lenah Adam; Grzegorz Kowalik; Andrew Tyler et al.

    Frontiers in Cardiovascular Medicine, Vol. 11 · 2024 · English · DOAJ Scopus

    BackgroundSimultaneous multi-slice (SMS) bSSFP imaging enables stress myocardial perfusion imaging with high spatial resolution and increased spatial coverage. Standard parallel imaging techniques (e.g., TGRAPPA) can be used for image reconstruction but result in high noise level. Alternatively…

  9. Journal Article

    Feasibility and impact of using an automated user interface for proton spectroscopy in multiparametric MRI of the prostate

    Mohamed M. H. Abd Ellah; Christian Kremser; Werner Judmaier et al.

    The Egyptian Journal of Radiology and Nuclear Medicine, Vol. 51 No. 1 · 2020 · English · DOAJ Scopus

    Abstract Background Multiparametric MRI including MR spectroscopy has recently gained much acceptance being a non-invasive imaging modality for the evaluation of prostate cancer. This study aimed to evaluate the reliability and effectiveness of an assisted workflow for guided and automated…

  10. Journal Article

    Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease

    Anastasia Fotaki; Kuberan Pushparajah; Christopher Rush et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 26 No. 1 · 2024 · English · DOAJ Scopus

    Background: Three dimensional, whole-heart (3DWH) MRI is an established non-invasive imaging modality in patients with congenital heart disease (CHD) for the diagnosis of cardiovascular morphology and for clinical decision making. Current techniques utilise diaphragmatic navigation (dNAV) for…

  11. Journal Article

    Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance

    Teresa Correia; Giulia Ginami; Imran Rashid et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 22 No. 1 · 2020 · English · DOAJ Scopus

    Abstract Background The free-breathing 3D whole-heart T2-prepared Bright-blood and black-blOOd phase SensiTive inversion recovery (BOOST) cardiovascular magnetic resonance (CMR) sequence was recently proposed for simultaneous bright-blood coronary CMR angiography and black-blood late gadolinium…

  12. Journal Article

    3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST

    Aurélien Bustin; Imran Rashid; Gastao Cruz et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 22 No. 1 · 2020 · English · DOAJ Scopus

    Abstract Background To enable free-breathing whole-heart sub-millimeter resolution coronary magnetic resonance angiography (CMRA) in a clinically feasible scan time by combining low-rank patch-based undersampled reconstruction (3D-PROST) with a highly accelerated non-rigid motion correction…

  13. Journal Article

    Automated segmentation of long and short axis DENSE cardiovascular magnetic resonance for myocardial strain analysis using spatio-temporal convolutional neural networks

    Hugo Barbaroux; Karl P. Kunze; Radhouene Neji et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 25 No. 1 · 2023 · English · DOAJ Scopus

    Abstract Background Cine Displacement Encoding with Stimulated Echoes (DENSE) facilitates the quantification of myocardial deformation, by encoding tissue displacements in the cardiovascular magnetic resonance (CMR) image phase, from which myocardial strain can be estimated with high accuracy and…

  14. Journal Article Full text

    MR Elastography Using the Gravitational Transducer

    Omar Isam Darwish; Vitali Koch; Thomas J. Vogl et al.

    Sensors, Vol. 24 No. 24 · 2024 · English · DOAJ Scopus

    MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity. Currently, hepatic MR elastography is deployed in the clinic to assess liver fibrosis in MAFLD patients. In addition, research has demonstrated MR…

  15. Journal Article

    Efficient non-contrast enhanced 3D Cartesian cardiovascular magnetic resonance angiography of the thoracic aorta in 3 min

    Anastasia Fotaki; Camila Munoz; Yaso Emanuel et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 24 No. 1 · 2022 · English · DOAJ Scopus

    Abstract Background The application of cardiovascular magnetic resonance angiography (CMRA) for the assessment of thoracic aortic disease is often associated with prolonged and unpredictable acquisition times and residual motion artefacts. To overcome these limitations, we have integrated…

  16. Journal Article

    3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging

    Giorgia Milotta; Camila Munoz; Karl P. Kunze et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 23 No. 1 · 2021 · English · DOAJ Scopus

    Abstract Purpose To develop a free-breathing whole-heart isotropic-resolution 3D late gadolinium enhancement (LGE) sequence with Dixon-encoding, which provides co-registered 3D grey-blood phase-sensitive inversion-recovery (PSIR) and complementary 3D fat volumes in a single scan of 0.99) were…

  17. Journal Article

    Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T

    Muhummad Sohaib Nazir; Radhouene Neji; Peter Speier et al.

    Journal of Cardiovascular Magnetic Resonance, Vol. 20 No. 1 · 2018 · English · DOAJ Scopus

    Abstract Background Simultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free…