Biblio Discovery — Demo Discovery Service

9 hasil untuk "Varun Sabu Sam"

Menampilkan 1–9 · 0,20 detik · RSS

  1. Artikel Jurnal

    Investigation on load deflection behavior of galvanized iron based cold formed steel sections with web holes under standard fire temperature

    Varun Sabu Sam; N. Anand; Diana Andrushia dkk.

    Heliyon, Vol. 11 No. 16 · 2025 · Inggris · DOAJ Scopus

    Cold-formed steel (CFS) sections are increasingly being used in construction to support small-scale loads. These sections are unique in that they are manufactured without the use of heat. Understanding the behavior of CFS sections when its exposed to fire or very high temperatures is crucial. In…

  2. Artikel Jurnal

    Influence of profile on fire performance of cold-formed galvanised iron built-up section with bolted connection under standard fire temperature

    Varun Sabu Sam; N. Anand; Chady EL Hachem dkk.

    Frontiers in Built Environment, Vol. 11 · 2025 · Inggris · DOAJ Scopus

    This paper aims to investigate the flexural behavior of Galvanized Iron (GI) based CFS built-up beams with lipped channels and lipped channel with different stiffener arrangements when exposed to prolonged periods of elevated temperature. Seven built-up beam specimens, each consisting of two lipped…

  3. Artikel Jurnal

    Influence of heating cooling regime on the buckling capacity of galvanized iron-based cold-formed steel columns with welded connections

    Varun Sabu Sam; N. Anand; Andrainik Iswarary dkk.

    Journal of Infrastructure Preservation and Resilience, Vol. 6 No. 1 · 2025 · Inggris · DOAJ Scopus

    Abstract This study provides valuable insights into the axial resistance of two different configurations and identifies different failure modes in specimens subjected to various temperatures and cooling methods. Fire exposure tests were conducted on galvanized iron (GI) based CFS columns with…

  4. Artikel Jurnal Teks lengkap

    Flexural Behavior of Galvanized Iron Based Cold-Formed Steel Back-to-Back Built-Up Beams at Elevated Temperatures

    Varun Sabu Sam; Anand Nammalvar; Diana Andrushia dkk.

    Buildings, Vol. 14 No. 8 · 2024 · Inggris · DOAJ Scopus

    Cold-formed steel (CFS) sections have become popular in construction due to several advantages over structural steel. However, research on the performance of galvanized iron (GI)-based CFS under high temperatures, especially regarding its flexural behavior, has been limited. This study extensively…

  5. Artikel Jurnal

    Improving the post-fire performance of reinforced concrete beams with lightweight plaster

    Daniel Paul Thanaraj; Varun Sabu Sam; N. Anand dkk.

    Case Studies in Construction Materials, Vol. 23 · 2025 · Inggris · DOAJ Scopus

    Structural fires pose significant risks to the built environment, making fire resistance a critical design consideration for reinforced concrete (RC) structures. Elevated temperatures during fires reduce the strength and stiffness of both concrete and steel reinforcement, compromising load-bearing…

  6. Artikel Jurnal

    Post fire flexural behavior of mild steel based cold-formed built-up beams exposed to elevated temperature

    Varun Sabu Sam; N. Anand; Mirvat Abdallah dkk.

    Frontiers in Built Environment, Vol. 10 · 2024 · Inggris · DOAJ Scopus

    The use of back-to-back built-up channel beams in cold-formed steel (CFS) structures is steadily rising. The growing demand for CFS sections as a cost-effective design solution has driven the development of these CFS built-up sections. Despite this, there has been limited research on the…

  7. Artikel Jurnal Teks lengkap

    Effect of Protective Coatings on Post-Fire Performance and Behavior of Mild Steel-Based Cold-Formed Steel Back-to-Back Channel Columns with Bolted Connections

    Varun Sabu Sam; Anand Nammalvar; Andrainik Iswarary dkk.

    Fire, Vol. 8 No. 3 · 2025 · Inggris · DOAJ Scopus

    This study investigates the buckling performance of built-up cold-formed steel (CFS) columns, with a focus on how different thermal exposures and cooling strategies influence their susceptibility to various failure mechanisms. Addressing the gap in the literature on the fire behavior of mild steel…

  8. Artikel Jurnal

    Investigation on Residual Mechanical Properties of Galvanized Iron Cold-Formed Steel Sections Exposed to Elevated Temperatures

    Varun Sabu Sam; Anand N; Garry Wegara K Marak dkk.

    Electronic Journal of Structural Engineering, Vol. 24 No. 1 · 2024 · Inggris · DOAJ Scopus

    Cold-formed steel (CFS) sections are used to construct medium and low-rise structures designed to carry small-scale loads. CFS sections are manufactured without the application of heat. Therefore, it is crucial to comprehend the properties of CFS sections which are exposed to fire or elevated…

  9. Artikel Jurnal Teks lengkap

    Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations

    Varun Sabu Sam; Garry Wegara K Marak; Anand Nammalvar dkk.

    Fire, Vol. 7 No. 9 · 2024 · Inggris · DOAJ Scopus

    Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how…