18 hasil untuk "Wonjoong Cheon"
Menampilkan 1–18 · 0,36 detik · RSS
-
Artikel Jurnal Teks lengkap
Bridging Photoacoustic and Protoacoustic Imaging: Material Heterogeneity Effects on Proton Range Verification Using Time-of-Flight Analysis
Photoacoustic and protoacoustic imaging share the common principle of acoustic wave generation through different excitation sources: optical absorption vs. proton Bragg-peak. These acoustic signals exhibit heterogeneity within the tissue, which strongly influence wave propagation and detection…
-
Artikel Jurnal Teks lengkap
Clinical applicability of deep learning-based respiratory signal prediction models for four-dimensional radiation therapy
For accurate respiration gated radiation therapy, compensation for the beam latency of the beam control system is necessary. Therefore, we evaluate deep learning models for predicting patient respiration signals and investigate their clinical feasibility. Herein, long short-term memory (LSTM)…
-
Artikel Jurnal
Dictionary-Augmented Large Language Model Postprocessing for Bilingual Code-Switched Medical Speech Recognition: Development and Evaluation Study
Abstract BackgroundClinical documentation burden contributes significantly to physician burnout, with health care professionals spending much of their time on electronic health record interactions. Automatic speech recognition (ASR) systems offer a promising solution; however, their application in…
-
Artikel Jurnal Teks lengkap
Deep-learning-based segmentation using individual patient data on prostate cancer radiation therapy.
PurposeOrgan-at-risk segmentation is essential in adaptive radiotherapy (ART). Learning-based automatic segmentation can reduce committed labor and accelerate the ART process. In this study, an auto-segmentation model was developed by employing individual patient datasets and a deep-learning-based…
Juga tersedia di: PLOS
-
Artikel Jurnal Teks lengkap
Development of a time-resolved mirrorless scintillation detector
Purpose: We developed a compact and lightweight time-resolved mirrorless scintillation detector (TRMLSD) employing image processing techniques and a convolutional neural network (CNN) for high-resolution two-dimensional (2D) dosimetry. Methods: The TRMLSD comprises a camera and an inorganic…
Juga tersedia di: DOAJ
-
Artikel Jurnal Teks lengkap
Hounsfield unit change in metastatic abdominal lymph nodes treated with combined hyperthermia and radiotherapy
Objective : Hyperthermia has been safely employed in conjunction with low to moderate doses of radiotherapy (RT) to achieve notable tumor responses in cases of previously treated and recurrent malignancies. However, the radiologic monitoring of combined hyperthermia and RT (HTRT) is not extensively…
Juga tersedia di: DOAJ
-
Artikel Jurnal
Performance enhancement method by using the probabilistic estimation for kidney tumor segmentation
PurposeEnsemble methods can enhance segmentation performance, but their effectiveness depends on the integration strategy. We investigated whether the STAPLE algorithm’s probabilistic framework could effectively leverage model diversity from different loss functions to improve kidney tumor…
-
Artikel Jurnal
Technical evaluation of non-coplanar lattice radiotherapy: achieving directional VPDR uniformity with a 5-mm leaf width multi-leaf collimator
PurposeSpatially fractionated radiation therapy (SFRT) creates alternating high-dose peaks and low-dose valleys for treating bulky tumors, with optimal biological effects associated with sufficient spatial dose modulation across the tumor volume. Coplanar lattice radiotherapy (LRT) demonstrated…
-
Artikel Jurnal
Deep learning method for prediction of patient-specific dose distribution in breast cancer
Abstract Background Patient-specific dose prediction improves the efficiency and quality of radiation treatment planning and reduces the time required to find the optimal plan. In this study, a patient-specific dose prediction model was developed for a left-sided breast clinical case using deep…
-
Artikel Jurnal
Dosimetric comparison of TomoTherapy and non-coplanar VMAT for hippocampal-avoidance prophylactic cranial irradiation
PurposeTo compare the dosimetric characteristics of non-coplanar volumetric modulated arc therapy (VMAT) and TomoTherapy for hippocampal-avoidance prophylactic cranial irradiation (HA-PCI) in small cell lung cancer (SCLC) patients.MethodsTen SCLC patients who received HA-PCI were retrospectively…
-
Artikel Jurnal
A preliminary study of linear accelerator-based spatially fractionated radiotherapy
PurposeThis study aimed to provide quantitative information for implementing Lattice radiotherapy (LRT) using a medical linear accelerator equipped with the Millennium 120 multi-leaf collimator (MLC). The research systematically evaluated the impact of varying vertex diameters and separations on…
-
Artikel Jurnal
Beam Angle Optimization for Double-Scattering Proton Delivery Technique Using an Eclipse Application Programming Interface and Convolutional Neural Network
To automatically identify optimal beam angles for proton therapy configured with the double-scattering delivery technique, a beam angle optimization method based on a convolutional neural network (BAODS-Net) is proposed. Fifty liver plans were used for training in BAODS-Net. To generate a sequence…
-
Artikel Jurnal
Feasibility of optimal vertex size and spacing for lattice radiotherapy implementation using helical tomotherapy
PurposeLattice radiotherapy (LRT), a type of spatially fractionated radiotherapy (SFRT), delivers high dose at specific volumes of lattice structure within the tumor to create a low valley-to-peak dose ratio (VPDR). This study aims to evaluate the feasibility of implementing SFRT using helical…