Biblio Discovery — Demo Discovery Service

20 hasil untuk "Po-Jen Shih"

Menampilkan 1–20 · 0,47 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Frequency Function in Atomic Force Microscopy Applied to a Liquid Environment

    Po-Jen Shih

    Sensors, Vol. 14 No. 6 · 2014 · Inggris · DOAJ Scopus

    Scanning specimens in liquids using commercial atomic force microscopy (AFM) is very time-consuming due to the necessary try-and-error iteration for determining appropriate triggering frequencies and probes. In addition, the iteration easily contaminates the AFM tip and damages the samples, which…

  2. Artikel Jurnal Teks lengkap

    Tip-Jump Response of an Amplitude-Modulated Atomic Force Microscope

    Po-Jen Shih

    Sensors, Vol. 12 No. 5 · 2012 · Inggris · DOAJ Scopus

    The dynamic behaviors of an Atomic Force Microscope are of interest, and variously unpredictable phenomena are experimentally measured. In practical measurements, researchers have proposed many methods for avoiding these uncertainties. However, causes of these phenomena are still hard to…

  3. Artikel Jurnal Teks lengkap

    Tip Effect of the Tapping Mode of Atomic Force Microscope in Viscous Fluid Environments

    Hua-Ju Shih; Po-Jen Shih

    Sensors, Vol. 15 No. 8 · 2015 · Inggris · DOAJ Scopus

    Atomic force microscope with applicable types of operation in a liquid environment is widely used to scan the contours of biological specimens. The contact mode of operation allows a tip to touch a specimen directly but sometimes it damages the specimen; thus, a tapping mode of operation may…

  4. Artikel Jurnal Teks lengkap

    Manufacturing and Characterization of a Thermoelectric Energy Harvester Using the CMOS-MEMS Technology

    Shih-Wen Peng; Po-Jen Shih; Ching-Liang Dai

    Micromachines, Vol. 6 No. 10 · 2015 · Inggris · DOAJ Scopus

    The fabrication and characterization of a thermoelectric energy harvester using the complementary metal oxide semiconductor (CMOS)-microelectromechanical system (MEMS) technology were presented. The thermoelectric energy harvester is composed of eight circular energy harvesting cells, and each cell…

  5. Artikel Jurnal Teks lengkap

    Tip Pressure on Semicircular Specimens in Tapping Mode Atomic Force Microscopy in Viscous Fluid Environments

    Hua-Ju Shih; Ching-Liang Dai; Po-Jen Shih

    Sensors, Vol. 17 No. 10 · 2017 · Inggris · DOAJ Scopus

    Tapping mode (TM) atomic force microscopy (AFM) in a liquid environment is widely used to measure the contours of biological specimens. The TM triggers the AFM probe approximately at the resonant frequencies and controls the tip such that it periodically touches the specimen along the scanning…

  6. Artikel Jurnal Teks lengkap

    An Acetone Microsensor with a Ring Oscillator Circuit Fabricated Using the Commercial 0.18 μm CMOS Process

    Ming-Zhi Yang; Ching-Liang Dai; Po-Jen Shih

    Sensors, Vol. 14 No. 7 · 2014 · Inggris · DOAJ Scopus

    This study investigates the fabrication and characterization of an acetone microsensor with a ring oscillator circuit using the commercial 0.18 μm complementary metal oxide semiconductor (CMOS) process. The acetone microsensor contains a sensitive material, interdigitated electrodes and a…

  7. Artikel Jurnal

    Development and validation of an intuitive biomechanics-based method for intraocular pressure measurement: a modal analysis approach

    Francis Li-Tien Hsu; Po-Jen Shih; I.-Jong Wang

    BMC Ophthalmology, Vol. 23 No. 1 · 2023 · Inggris · DOAJ Scopus

    Abstract Background Current intraocular pressure (IOP) measurements based on non-contact tonometry are derived from statistics-driven equations and lack biomechanical significance, which often leads to under-estimation in post-refractive surgery cornea. This study aims to introduce and validate…

  8. Artikel Jurnal Teks lengkap

    A Three-Axis Magnetic Field Microsensor Fabricated Utilizing a CMOS Process

    Jian-Zhi Tseng; Po-Jen Shih; Cheng-Chih Hsu dkk.

    Applied Sciences, Vol. 7 No. 12 · 2017 · Inggris · DOAJ Scopus

    This study develops a three-axis magnetic field (MF) microsensor manufactured by a complementary metal oxide semiconductor (CMOS) process. The MF microsensor contains a ring emitter, four bases, and eight collectors. Sentaurus TCAD was used to simulate the microsensor characterization. The STI…

  9. Artikel Jurnal Teks lengkap

    Fabrication and Characterization of CMOS-MEMS Thermoelectric Micro Generators

    Mao-Chen Liu; Ching-Liang Dai; Po-Jen Shih dkk.

    Sensors, Vol. 10 No. 2 · 2010 · Inggris · DOAJ Scopus

    This work presents a thermoelectric micro generator fabricated by the commercial 0.35 μm complementary metal oxide semiconductor (CMOS) process and the post-CMOS process. The micro generator is composed of 24 thermocouples in series. Each thermocouple is constructed by p-type and n-type polysilicon…

  10. Artikel Jurnal Teks lengkap

    Fabrication and Characterization of Flexible Thermoelectric Generators Using Micromachining and Electroplating Techniques

    Wnag-Lin Lee; Po-Jen Shih; Cheng-Chih Hsu dkk.

    Micromachines, Vol. 10 No. 10 · 2019 · Inggris · DOAJ Scopus

    This study involves the fabrication and measurement of a flexible thermoelectric generator (FTG) using micromachining and electroplating processes. The area of the FTG is 46 × 17 mm2, and it is composed of 39 thermocouples in series. The thermoelectric materials that are used for the FTG are copper…

  11. Artikel Jurnal Teks lengkap

    Manufacturing and Characterization of Three-Axis Magnetic Sensors Using the Standard 180 nm CMOS Technology

    Chi-Han Wu; Po-Jen Shih; Yao-Chuan Tsai dkk.

    Sensors, Vol. 21 No. 21 · 2021 · Inggris · DOAJ Scopus

    A three-axis micro magnetic sensor (MS) is developed based on the standard 180 nm complementary metal oxide semiconductor (CMOS) technology. The MS designs two magnetic sensing elements (MSEs), which consists of an x/y-MSE and an z-MSE, to reduce cross-sensitivity. The x/y-MSE is constructed by an…

  12. Artikel Jurnal Teks lengkap

    Manufacturing and Testing of Radio Frequency MEMS Switches Using the Complementary Metal Oxide Semiconductor Process

    Zung-You Tsai; Po-Jen Shih; Yao-Chuan Tsai dkk.

    Sensors, Vol. 21 No. 4 · 2021 · Inggris · DOAJ Scopus

    A radio frequency microelectromechanical system switch (MSS) manufactured by the complementary metal oxide semiconductor (CMOS) process is presented. The MSS is a capacitive shunt type. Structure for the MSS consists of coplanar waveguide (CPW) lines, a membrane, and springs. The membrane locates…

  13. Artikel Jurnal Teks lengkap

    Low-Concentration Ammonia Gas Sensors Manufactured Using the CMOS–MEMS Technique

    Wei-Chun Shen; Po-Jen Shih; Yao-Chuan Tsai dkk.

    Micromachines, Vol. 11 No. 1 · 2020 · Inggris · DOAJ Scopus

    This study describes the fabrication of an ammonia gas sensor (AGS) using a complementary metal oxide semiconductor (CMOS)−microelectromechanical system (MEMS) technique. The structure of the AGS features interdigitated electrodes (IDEs) and a sensing material on a silicon substrate. The IDEs are…

  14. Artikel Jurnal Teks lengkap

    Magnetic Micro Sensors with Two Magnetic Field Effect Transistors Fabricated Using the Commercial Complementary Metal Oxide Semiconductor Process

    Wei-Ren Chen; Yao-Chuan Tsai; Po-Jen Shih dkk.

    Sensors, Vol. 20 No. 17 · 2020 · Inggris · DOAJ Scopus

    The fabrication and characterization of a magnetic micro sensor (MMS) with two magnetic field effect transistors (MAGFETs) based on the commercial complementary metal oxide semiconductor (CMOS) process are investigated. The magnetic micro sensor is a three-axis sensing type. The structure of the…

  15. Artikel Jurnal Teks lengkap

    Synergic Effect of Novel WS2 Carriers Holding Spherical Cobalt Ferrite @cubic Fe3O4 (WS2/s-CoFe2O4@c-Fe3O4) Nanocomposites in Magnetic Resonance Imaging and Photothermal Therapy for Ocular Treatments and Investigation of Corneal Endothelial Cell Migration

    Shadie Hatamie; Po-Jen Shih; Bo-Wei Chen dkk.

    Nanomaterials, Vol. 10 No. 12 · 2020 · Inggris · DOAJ Scopus

    The design of novel materials to use simultaneously in an ocular system for driven therapeutics and wound healing is still challenging. Here, we produced nanocomposites of tungsten disulfide carriers with spherical cobalt ferrite nanoparticles (NPs) as core inside a cubic iron oxide NPs shell…

  16. Artikel Jurnal

    Correlation between corneal dynamic responses and keratoconus topographic parameters

    Hsi-Yun Tai; Jun-Ji Lin; Yi-Hung Huang dkk.

    Journal of International Medical Research, Vol. 50 · 2022 · Inggris · DOAJ Scopus

    Objective To investigate the correlation between corneal biomechanical properties and topographic parameters using machine learning networks for automatic severity diagnosis and reference benchmark construction. Methods This was a retrospective study involving 31 eyes from 31 patients with…

  17. Artikel Jurnal

    Changes in Intraocular Pressure after Transepithelial Photorefractive Keratectomy and Femtosecond Laser In Situ Keratomileusis

    Chien-Chih Chou; Po-Jen Shih; Hung-Chou Lin dkk.

    Journal of Ophthalmology, Vol. 2021 · 2021 · Inggris · DOAJ Scopus

    Purpose. To investigate the changes in intraocular pressure (IOP) and biomechanically corrected IOP (bIOP) in patients undergoing transepithelial photorefractive keratectomy (TPRK) and femtosecond laser in situ keratomileusis (FS-LASIK) and to determine the effects of preoperative biomechanical…

  18. Artikel Jurnal

    Eye orbit effects on eyeball resonant frequencies and acoustic tonometer measurements

    Po-Jen Shih; Shao-Jie Wu; Ya-Hsing Sung dkk.

    Scientific Reports, Vol. 12 No. 1 · 2022 · Inggris · DOAJ Scopus

    Abstract The eye orbit has mechanical and acoustic characteristics that determine resonant frequencies and amplify acoustic signals in certain frequency ranges. These characteristics also interfere with the acoustic amplitudes and frequencies of eyeball when measured with an acoustic tonometer. A…

  19. Artikel Jurnal

    Estimation of the Corneal Young’s Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging

    Po-Jen Shih; Chun-Ju Huang; Tzu-Han Huang dkk.

    Journal of Ophthalmology, Vol. 2017 · 2017 · Inggris · DOAJ Scopus

    Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their…