20 hasil untuk "Markus Windolf"
Menampilkan 1–20 · 0,91 detik · RSS
-
Artikel Jurnal
Computational optimisation of screw orientations for improved locking plate fixation of proximal humerus fractures
Background: The implant-related failure risks of proximal humerus plates remain high, and therefore, improved solutions are needed. Systematic and efficient computational analyses can assist design optimisation of implant systems and may help reduce complication rates. Methods: A previously…
-
Artikel Jurnal
On the importance of accurate elasto-plastic material properties in simulating plate osteosynthesis failure
Background: Plate osteosynthesis is a widely used technique for bone fracture fixation; however, complications such as plate bending remain a significant clinical concern. A better understanding of the failure mechanisms behind plate osteosynthesis is crucial for improving treatment outcomes. This…
-
Artikel Jurnal
Growth modulation of angular deformities with a novel constant force implant concept-preclinical results
Abstract Purpose Varus-valgus deformities in children and adolescents are often corrected by temporary hemi-epiphysiodesis, in which the physis is bridged by an implant to inhibit growth. With standard implant solutions, the acting forces cannot be regulated, rendering the correction difficult to…
-
Artikel Jurnal Teks lengkap
In Vitro Testing and Clinical Handling of a Novel Implant Positioning Technology for Proximal Humeral Plating
Background and Objectives: Fractures of the proximal humerus are common, particularly in elderly populations. Anatomical locking plates target stabilization with a multitude of screws spanning into the humeral head. Sound implant placement and screw length determination are key for a successful…
-
Artikel Jurnal Teks lengkap
Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking
Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated…
-
Artikel Jurnal
X-Ray based navigation system for torsional correction - first clinical data
Aims and Objectives: It is well known that treatment of femoral shaft fractures can lead into torsional malalignment. In up to 15% of these cases a torsional correction is necessary. Further there are congenital torsional abnormities causing disbalances in the knee joint. In both cases a torsional…
-
Artikel Jurnal Teks lengkap
Programable Active Fixator System for Systematic In Vivo Investigation of Bone Healing Processes
This manuscript introduces a programable active bone fixator system that enables systematic investigation of bone healing processes in a sheep animal model. In contrast to previous systems, this solution combines the ability to precisely control the mechanical conditions acting within a fracture…
-
Artikel Jurnal
Bone cement allocation analysis in artificial cancellous bone structures
Background: One of the most serious adverse events potentially occurring during vertebroplasty is cement leakage. Associated risks for the patient could be reduced if cement filling is preoperatively planned. This requires a better understanding of cement flow behaviour. Therefore, the aim of the…
-
Artikel Jurnal
Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures
Joint-preserving surgical treatment of complex unstable proximal humerus fractures remains challenging, with high failure rates even following state-of-the-art locked plating. Enhancement of implants could help improve outcomes. By overcoming limitations of conventional biomechanical testing…
-
Artikel Jurnal Teks lengkap
Short-Term Bone Healing Response to Mechanical Stimulation—A Case Series Conducted on Sheep
It is well known that mechanical stimulation promotes indirect fracture healing by triggering callus formation. We investigated the short-term response of healing tissue to mechanical stimulation to compare the changes in tissue stiffness during stimulation and resting phases in a preclinical…
-
Artikel Jurnal Teks lengkap
Microstructural Parameters of Bone Evaluated Using HR-pQCT Correlate with the DXA-Derived Cortical Index and the Trabecular Bone Score in a Cohort of Randomly Selected Premenopausal Women
Background: Areal bone mineral density is predictive for fracture risk. Microstructural bone parameters evaluated at the appendicular skeleton by high-resolution peripheral quantitative computed tomography (HR-pQCT) display differences between healthy patients and fracture patients. With the simple…
Juga tersedia di: DOAJ
-
Artikel Jurnal Teks lengkap
Continuous Implant Load Monitoring to Assess Bone Healing Status—Evidence from Animal Testing
Background and Objectives: Fracture healing is currently assessed through qualitative evaluation of radiographic images, which is highly subjective in nature. Radiographs can only provide snapshots in time, which are limited due to logistics and radiation exposure. We recently proposed assessing…
-
Artikel Jurnal Teks lengkap
Continuous Rod Load Monitoring to Assess Spinal Fusion Status–Pilot In Vivo Data in Sheep
Background and Objectives: Spinal fusion is an effective and widely accepted intervention. However, complications such as non-unions and hardware failures are frequently observed. Radiologic imaging and physical examination are still the gold standards in the assessment of spinal fusion, despite…
-
Artikel Jurnal
Biomechanical comparison between standard and inclined screw orientation in dynamic hip screw side-plate fixation: The lift-off phenomenon
Background: Common failure modes of dynamic hip screw are cut-out and lift-off. To minimize the latter, distal screws can be inserted in different orientations. However, the effectiveness remains controversial. The aim of this study was to biomechanically investigate the influence of distal screw…
-
Artikel Jurnal Teks lengkap
Impact of Bone Cement Augmentation on the Fixation Strength of TFNA Blades and Screws
Background and Objectives: Hip fractures constitute the most debilitating complication of osteoporosis with steadily increasing incidences in the aging population. Their intramedullary nailing can be challenging because of poor anchorage in the osteoporotic femoral head. Cement augmentation of…
-
Artikel Jurnal
Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
Aims: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation…
-
Artikel Jurnal
Experimental and virtual testing of bone-implant systems equipped with the AO Fracture Monitor with regard to interfragmentary movement
Introduction: The management of fractured bones is a key domain within orthopedic trauma surgery, with the prevention of delayed healing and non-unions forming a core challenge. This study evaluates the efficacy of the AO Fracture Monitor in conjunction with biomechanical simulations to better…
-
Artikel Jurnal
Irrigation of the intramedullary channel improves outcome of DAIR in a sheep model
Abstract The management of fracture-related infection (FRI) with Debridement, Antibiotics, Irrigation, and Implant Retention (DAIR) is an appealing option, but its suitability is restricted to a relatively narrow proportion of patients. This study aimed to create a large animal model of DAIR after…
-
Artikel Jurnal Teks lengkap
Statistical Morphology and Fragment Mapping of Complex Proximal Humeral Fractures
Background and Objectives: Proximal humerus fractures (PHFs) are common in the elderly, but the treatment results are often poor. A clear understanding of fracture morphology and distribution of cortical bone loss is important for improved surgical decision making, operative considerations, and new…