22 hasil untuk "Philipp Blanke"
Menampilkan 1–20 · 0,41 detik · RSS
-
Artikel Jurnal
Personalized intervention cardiology with transcatheter aortic valve replacement made possible with a non-invasive monitoring and diagnostic framework
Abstract One of the most common acute and chronic cardiovascular disease conditions is aortic stenosis, a disease in which the aortic valve is damaged and can no longer function properly. Moreover, aortic stenosis commonly exists in combination with other conditions causing so many patients suffer…
-
Artikel Jurnal
Repeat Transcatheter Aortic Valve Replacement and Follow-Up of Embolized Transcatheter Heart Valve After 13 Years
A 79-year-old woman was treated with a 23-mm balloon-expandable transcatheter heart valve (THV) that was initially complicated by an embolized THV requiring deployment in the descending aorta. She presented 13-years later with a degenerated bioprosthesis requiring redo THV. Pre-procedural computed…
-
Artikel Jurnal
Cardiovascular risk assessment enhanced by automated machine learning in a multi-phase study
Abstract Cardiovascular diseases (CVDs) are the leading cause of death worldwide, and current predictors such as lipoprotein (a) [Lp(a)] and risk scores have limitations. Automated machine learning (AutoML) offers the potential to improve CVD risk prediction by processing large datasets and…
-
Artikel Jurnal
Transcatheter heart valve commissural alignment: an updated review
Transcatheter aortic valve replacement (TAVR) indications recently extended to lower surgical risk patients with longer life expectancy. Commissural alignment (CA) is one of the emerging concepts and is becoming one of the cornerstones of the TAVR procedure in a patient with increased longevity…
-
Artikel Jurnal
Case Report: Stretching the limits—late valvuloplasty for THV dysfunction following redo mitral valve-in-valve implantation
Late balloon valvuloplasty can be used to treat under-expansion-related transcatheter heart valve (THV) dysfunction. Whether this can be performed following redo-THV implantation is unknown. Herein, we report a case of a 72-year-old male presenting with symptomatic gradient elevation following redo…
-
Artikel Jurnal Teks lengkap
TAVR for All? The Surgical Perspective
In spite of the noninferiority of transcatheter aortic valve replacement (TAVR) in high- and intermediate-risk patients, there are still obstacles that need to be overcome before the procedure is further expanded and clinically integrated. The lack of evidence on the long-term durability of the…
-
Artikel Jurnal
A Simplified Fluoroscopic Method for Commissural Alignment Assessment With a Balloon-Expandable Transcatheter Heart Valve
We sought to assess commissural alignment of the balloon-expandable valve on fluoroscopy. Commissural alignment was defined on fluoroscopy in 20 patients according to alignment of the valve commissural posts in the 3-cusp and the cusp-overlap view and correlated with post–transcatheter aortic valve…
-
Artikel Jurnal Teks lengkap
Novel Magnetic Resonance Imaging Tools for Hypertrophic Cardiomyopathy Risk Stratification
Hypertrophic cardiomyopathy (HCM) is a common genetic disorder with a well described risk of sudden cardiac death; however, risk stratification has remained a challenge. Recently, novel parameters in cardiac magnetic resonance imaging (CMR) have shown promise in helping to improve upon current risk…
-
Artikel Jurnal
Assessing the Hemodynamic Impact of Anterior Leaflet Laceration in Transcatheter Mitral Valve Replacement: An in silico Study
BackgroundA clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted.AimsTo quantify the hemodynamic impact of LAMPOON…
-
Artikel Jurnal
Evaluation of an Explanted Tiara Transcatheter Mitral Valve
Post-explant (ex vivo) evaluation of medical devices is an essential part of quality assurance, quality improvement, and further device development. Central to this is detailed pathological analysis. Here, we provide the first such evaluation of an explanted Tiara transcatheter mitral valve…
-
Artikel Jurnal
Comparison of performance of self-expanding and balloon-expandable transcatheter aortic valvesCentral MessagePerspective
Objective: To evaluate the flow dynamics of self-expanding and balloon-expandable transcatheter aortic valves pertaining to turbulence and pressure recovery. Transcatheter aortic valves are characterized by different designs that have different valve performance and outcomes. Methods: Assessment of…
-
Artikel Jurnal
Mixed Valvular Disease Following Transcatheter Aortic Valve Replacement: Quantification and Systematic Differentiation Using Clinical Measurements and Image‐Based Patient‐Specific In Silico Modeling
Background Mixed valvular disease (MVD), mitral regurgitation (MR) from pre‐existing disease in conjunction with paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR), is one of the most important stimuli for left ventricle (LV) dysfunction, associated with cardiac…
-
Artikel Jurnal
Prediction of Underexpansion Following Transcatheter Aortic Valve Implantation and Efficacy of Balloon Postdilatation
Background: Transcatheter heart valve (THV) underexpansion following transcatheter aortic valve implantation (TAVI) is associated with elevated gradients, paravalvular leak, and/or risk of hypoattenuating leaflet thickening. We aimed to simulate TAVI using pre-TAVI computed tomography (CT) images…
-
Artikel Jurnal Teks lengkap
Subclinical Leaflet Thrombosis in Transcatheter and Surgical Bioprosthetic Valves
BACKGROUND: Subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion observed on 4-dimensional computed tomography (CT), may represent a form of bioprosthetic valve dysfunction. OBJECTIVES: The U.S. Food and Drug Administration mandated CT…
-
Artikel Jurnal Teks lengkap
Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical Research
-
Artikel Jurnal Teks lengkap
Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research
AIMS: The Valve Academic Research Consortium (VARC), founded in 2010, was intended to (i) identify appropriate clinical endpoints and (ii) standardize definitions of these endpoints for transcatheter and surgical aortic valve clinical trials. Rapid evolution of the field, including the emergence of…
-
Artikel Jurnal
Transcatheter Aortic Valve Implantation for Bioprosthetic Valve Failure: Placement of Aortic Transcatheter Valves 3 Aortic Valve-in-Valve Study
Background: Transcatheter aortic valve implantation is safe and effective for high-risk patients with bioprosthetic valve failure (BVF) but has not been studied in low- and intermediate-risk patients. One year outcomes of the PARTNER 3 Aortic Valve-in-valve (AViV) Study were evaluated. Methods…
-
Artikel Jurnal
A novel computational method to predict hypoattenuated leaflet thickening post-transcatheter aortic valve replacement using preprocedural computed tomography scansCentral MessagePerspective
Objective: Hypoattenuated leaflet thickening (HALT) is a computed tomography (CT) finding after transcatheter aortic valve replacement (TAVR) that is indicative of bioprosthetic valvular thrombosis. There are currently no standardized or validated methods for predicting HALT, which can cause…